Reference Case of Offshore Wind Measurement(Company J)
Case Study of Offshore Wind Measurement(Company J)
Location | Kyushu region (Off grid area) |
---|---|
Purpose | Environmental Assessment of Wind Power Generation |
Wind measurement by Doppler Lidar | |
Power consumption | Average 60W |
Load | Wind Cube V2. 1 (manufactured by LEOSPHERE) |
Fuel Cell System Specification | 2sets of EFOY 2400 Pro Duo JP (110W) are used. |
Output | AC100V |
DC24V | |
Methanol volume | 10 L × 8 pieces (80L) |
Storage amount of electricity | 80,000Wh |
Working Period | 56 days |
Issues | There is no grid power supply and it is difficult to access at site. It is very difficult to deliver the items to site. |
Solution | Small and transportable Fuel Cell solves the problem. Fuel supply is regularly accessed and handled by boats. |
BACK